Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch

Product Details
Customization: Available
Type: Microwave Sensor Switch
Standard: Standard
Still deciding? Get samples of US$ 20/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory
Secured Trading Service
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
  • Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
  • Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
  • Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
  • Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Find Similar Products

Basic Info.

Model NO.
G7IS
Transport Package
Inner Box + Carton
Specification
89*36mm
Origin
Guangdong, China
HS Code
85389000
Production Capacity
10000 Piece/Pieces Per Week

Packaging & Delivery

Package Size
9.00cm * 9.00cm * 5.00cm
Package Gross Weight
0.250kg

Product Description

Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Our infrared sensor switch has pyroelectric infrared sensor (PIR), ambient-light detection sensor and control module in one unit. The device automatically turns light ON/OFF when it detects motion and ambient light level. It is ideal for business use of convenience, energy efficiency, and security. It can be used in hotel aisles, stair hall, balcony, garage, classrooms, libraries, offices, meeting rooms, hospitals, warehouses, manufacturing places, factories, etc. This product has an adjustable time delay from between 50 seconds and 9 minutes, along with light sensitivity adjustment from 2 to 1000 LUX.
Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Automatic Detection Technology
When a person passes into or out of a sensor zone, the sensor detects motion and switches the lights ON. The lights will remain ON as long as there is an occupant in the room. When the space being monitored by the sensor is unoccupied for the preset time you've entered, the unit will switch the lights OFF.
Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Sensitivity, Time Delay Adjustment

When ambient light level lower than the preset setting, the sensor switch goes into normal operation. With adjusting SUN1, users can adjust the sensor switch from 5~500 LUX to adapt the actual need. The product also has an adjustable time delay from between 16 seconds and 350 seconds.

Curved Design
The design inspiration prevents the conflict feeling of the less curved design. Because of the curved design, and it is attached to the ceiling, it brings relaxed and natural feeling.
Dual Inductive Control (Import PIR, Photosensitive Control)
RE200BP PIR with high sensitivity and stability; energy saving photoresistance control, light only on when lighting is below set point as to achieve energy saving purpose.
Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Pyroelectric Infrared Processing Chip

BISS001 pyroelectric infrared processing chip with stable and reliable performance. It also possesses relay control load with high-peaked and stable contact.

Adjustable Lux and Delay Time Ceiling PIR Sensor Light SwitchHoneycomb Lenses for Superior Occupancy Detection
Taiwan imported honeycomb lenses offers higher sensitivity and wider detection range option than other similar products.
Ultralow-power Consumption
Self-power consumption within 0.026w/h, much more energy saving compared with similar products.
Lightening Protection Function
Special-made lightening protection device, effectively prevent high-pressured instant damage to the switch.

Adjustable Lux and Delay Time Ceiling PIR Sensor Light SwitchEasy Installation
Firstly, use 2 screws to secure the mounting box to the ceiling. Then drill a hole next to it, thread the wires through the hole, and match the sensor switch with the mounting box.
Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Product Internal Details
Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Wiring Diagram
Adjustable Lux and Delay Time Ceiling PIR Sensor Light Switch
Instruction

1. Install following the wiring diagram, after the careful check, connect the power supply. 45 seconds is needed for preheat. When a person passes into or out of a sensor zone, the sensor detects motion and switches the lights ON.

2. Product sensitivity is set up automatically from factory. No need for adjustment if not installed in special location.

3. Time delay adjustment: turn the timer rightward, extend time delay; leftward, then otherwise.

Attention

1 Disconnect electricity in wiring process; prevent over-loading short-circuit; put on electricity after installation.

2. Strictly follow the wiring installation diagram. Incorrect wiring would cause power supply line fault and damage to the switch.

3. Strictly forbidden to use in super power or it would also cause damage to device.

4. Please install the unit in the center of the detected area; avoid blocking the lenses to achieve maximized detection range. In addition, please install in the area with average lighting. If installed in shady coner, sensitivity of the sensor switch would be lower than the average ambient light, and the sensor would not switch the light on in faint sunlight. The sensor switch must avoid direct lighting from the lenses or it might cause flashing to the light.

5. In order to keep the high sensitivity, please install the sensor at least one meter away from the laader; please do not install the product in strong light environment and where there is strong cold or heat airflow; please also do not install near high-power radio-frenquency radiation (such as radio, interphone, antenna, etc.)
Parameters

Operating voltage  AC100-240V±10%
Detecting distance Height 2.5~4 meters, Radius3~5 meters
Installation Ceiling-mounted
Load type Incandescent light bulb, fluorescent lamp, compact fluorescent lamp, LED, etc.
Power Max. 0.5W
Capability of load Max. 1000W
Viewing area 360° degree field of view
Lighting detecting range  2~1000 LUX
Time delay 50 seconds~9 minutes (adjustable)
Environment temperature  -20ºC~60ºC
Shape Φ89x36mm
Reliable quality Lasts more than 500,000 times
 